- Large number of channels
- No power supply required
- Digital output for control
- Data acquisition software included
Do you need a data acquisition product with up to 11 input channels?
The Pico ADC-11 data loggers provide you with a low cost solution to your data acquisition needs. The ADC-11 provides you with 11 channels of analog input — all in a small unit that's easy-to-use.
Resolution and Accuracy
Two different versions of the ADC-11 are available: the ADC-11/10 features 10 bit resolution, whilst the ADC-11/12 has 12 bit resolution — making it suitable for detecting very small signal changes.
With data acquisition the accuracy of your measurements is paramount which is why the ADC-11/10 is accurate to within 1 %, and the ADC-11/12 to within 0.5 %.
USB or parallel — the choice is yours
The ADC-11 is available in both parallel and USB versions — making it easy to connect, regardless of the type of PC or laptop used.
With the USB ADC-11 you can connect up to 4 units to one PC — giving you up to 44 channels of data acquisition with a very low cost per channel.
|
No need for power supplies or batteries
The ADC-11 is powered directly by your PC — eliminating the need for batteries or a separate power supply, and making it ideal when you need a portable data acquisition solution.
Control alarms and other devices
The ADC-11 includes digital outputs — these can be used to control alarms or other devices, additionally these outputs can also be used to power sensors such as thermistors.
Data acquisition software
All products in the Pico data logger range come complete with PicoLog — this powerful, but flexible, data acquisition software allows you to collect, manipulate, analyze, and display and export data.
Updates to PicoLog are available from our website, and you can download a demo of PicoLog to see just how versatile it is.
Low cost data acquisition
If you need a data acquisition product capable of measuring a large number of channels the Pico ADC-11 offers you a low cost solution that does not require a power supply, can connect to both USB and parallel ports, and come complete with data acquisition software.
Terminal block
To simplify the connection of your sensors a terminal block is available for the ADC-11. This connects to the input of the ADC-11 and provides screw terminals to allow you to quickly connect and disconnect your sensors.
Specifications
| |
ADC-11/10 | USB ADC-11/10 | ADC-11/12 | USB ADC-11/12 |
| Number of channels |
11
|
| Digital outputs (3.3 V) |
1 |
2 |
1 |
2 |
| Sampling rate # |
10 kS/s |
20 kS/s |
10 kS/s |
20 kS/s |
| Input type |
Unipolar - single ended |
| Voltage ranges |
0 to 2.5 V
|
| Input connector |
D25 Female
|
| AC/DC coupling |
DC coupled
|
| Overload protection |
±30 V
|
| Accuracy |
1 %
|
0.5 %
|
| Input impedance |
>1 MΩ
|
| Resolution |
10 bits
|
12 bits
|
| Environmental |
20-30 °C for quoted accuracy, 0 to 70 °C overall. 20-90 %RH |
| PC connection |
Parallel |
USB 1.1 |
Parallel |
USB 1.1 |
| Power supply |
Powered directly from the PC
|
| Supplied software |
PicoScope (oscilloscope, spectrum analyser, meter), PicoLog (data logger), Drivers and examples (C, Delphi and Visual Basic, Labview, Agilent VEE6.1 and Excel) Software is supplied on CD and is compatible with Windows 98SE/ME/2000/XP |
|